17th edition consumer unit 17th edition glasgow 2014 Glasgow commonwealth Games 2014 metal consumer unit 24 hour emergency electrician Aceh Aleppo all trades company glasgow Archive Article Beauty BG Fuse Board Bikes Biograph boiler installer glasgow Browser Business business and technology news business technology news call out heating engineer cctv glasgow cctv news CERTIFICATES GLASGOW cheap kitchesn glasgow cheques christmas led lights clarkston electrician company health insurance compare private health insurance Consumer unit consumer units glasgow council electricians renfrewshire crookston electricians Culture currency Downloads eicr glasgow electric cars westend glasgow electric showers electricains clarkston glasgow ELECTRICAL CONTRACTOR electrical contractor crookston. Electrical contractor Glasgow electrical installation paisley electrical safety electrical testing london electrician electrician bearsden ELECTRICIAN EICR GLASGOW electrician glasgow electrician kitchens electricians electricians 24 hours glasgow electricians 24 hours london electricians bellahouston electricians birmingham electricians clarkston electricians east kilbride electricians giffnock electricians glasgow electricians glasgow city centre electricians hyndland westend glasgow electricians in giffnock electricians in glasgow electricians in greenock and port glasgow electricians in south side clarkston consumer unit clarkston electricians london electricians mosspark electricians niceic electricians paisley electricians west end glasgow electricians westend glasgow electricians westend glasogw eletricians newton mearns emergency call out electricians Event Fashion Favourite Feature Featured Posts Fellowship Flags Food Genel fusebox clarkston fusebox south side glasgow Gadgets Gallery Games gas central heating glasgow gas engineer gas fitter gas safe Gear giffnock electrical contractor giffnock electricians giffnock electricins giffnock spark giffock local electrician Glasgow glasgow electrical contractor Health health information technology health insurance quote History Holy info internet technology news Journalism landlord electrical safety check landlords electricians latest innovations in technology Life & style Magazine metal consumer unit Mine Movies Reviews Music Musik new business technology new consumer units new internet technology new technology for business new technology in business News NICEIC PAT TESTING pat testing glasgow Politics private health cover private health insurance private medical insurance Random Regional Reviews sejarah select electricians glasgow Shooting Slider solar power south side glasgow electrician Sports Surabaya Technology Templates testing glasgow TopDownload Travel travel health insurance travel money travellers Turkey Tutorial Tutorials UK ver Video wes electrical west end glasgow electricians westend electrical saftey WESTEND GALSGOW ELECTRICAL CONTRACTOR westend glasgow 24 hour emergency electrician westend glasgow 24 hours electricians westend glasgow electricians westend glasgow rewire Wisata

Dualsgstacked Col Print
From 1st December 2015, private landlords are responsible for ensuring that an electrical safety inspection of their property is carried out by a registered electrician at least every five years.

The new legislation explained

As of 1st December 2015, under sections 13(4A) and 19B(4) of the Housing (Scotland) Act 2006, private landlords in Scotland will be required by law to ensure that their properties are electrically safe.
This covers:
  • Any installations in the property for the supply of electricity
  • Electrical fixtures and fittings
  • Any appliances provided by the landlord under the tenancy.
Landlords must be able to prove that all of the above are in a reasonable state of repair and in proper working order.

So what do landlords need to do?

Landlords are required to ensure that regular electrical safety inspections are carried out by a competent person, and that anything that fails to pass the inspection is replaced or repaired immediately.
As a minimum, an electrical safety inspection must be carried out:
  • Before a tenancy starts, and
  • During the tenancy, at intervals of no more than five years from the date of the previous inspection.
A copy of the most recent electrical safety inspection reports must be provided to both new and retained tenants.
The person who conducts the checks must be employed by a firm that is a member of an accredited registration scheme operated by a body recognised by the Scottish Government � this will usually mean that they are registered with NICEIC or a member firm of the Electrical Contractors� Association of Scotland (SELECT).
Both the NICEIC and the Electrical Contractors' Association of Scotland (SELECT) provide online tools for finding local members.

Transitional Rules

the Scottish government guidelines details the transitional rules for the scheme.
  • It requires any new tenant to receive an EICR if they take up their tenancy after the 1st December 2015.
  • Any existing tenant to receive a copy of an EICR before the 1st December 2016 (unless their tenancy will end before that date).
  • If an EICR (or new installation certificate) is available for the property that was produced since 1st January 2012, this is still in its perceived 5 year lifecycle this is still valid (for 5 years from issue).  These do not need any PAT report.
  • Any EICR produced after 1st December 2015 will also need Appliance test reports.

What happens during the electrical safety inspection?

An electrical safety inspection has two parts:
  • An Electrical Installation Condition Report (EICR) � formerly known as a Periodic Inspection Report (PIR) � on the safety of the electrical installations, fixtures and fittings.
  • A Portable Appliance Test (PAT) on any portable appliances that you have provided by the landlord.
For the Electrical Installation Condition Report, the registered electrician will carry out checks of installations for the supply of electricity, electrical fittings (including but not limited to switches, sockets and light fittings) and fixed electrical equipment (including but not limited to boilers, panel and storage heaters and hard-wired smoke and fire detectors).
As a result, the electrician will produce an EICR document that highlights any problems using different classifications: code C1 indicating �danger present�, code C2 indicating �potentially dangerous� and code FI indicating �further investigation required�. Any remedial work that is undertaken as a result of the inspection will then be recorded on a Minor Electrical Installation Works Certificate.




1. Why are these changes being made?
Further to several household fires involving plastic consumer units, investigations by the Glasgow fire brigade, has concluded that a key cause of the fires was substandard cable connections made by the Electrician within the consumer unit.
These resulted in overheating, which subsequently ignited the plastic enclosure.
The draft of Amendment 3 proposes changes to the fire protection regulations in BS 7671 Wiring Regulations. If approved, these changes will be incorporated in the 17th Edition of the Wiring Regulations, due to be published in January 2015. IET Chief Engineer Geoff Cronshaw interviews London Fire Brigade investigator Charlie Pugsley to find out more about the reasons behind these changes


2. What constitutes a substandard cable connection?
Many factors may contribute to a substandard connection. Some of these are inadequate tightening of conductors in the internal devices� terminals or clamping the insulation of the cable rather than the conductor with the terminal screw.
In the third amendment, it is expected that the schedule of inspections for new installation work and condition report for existing installations, will require confirmation that all conductor connections within a consumer unit or distribution board are correctly located in terminals, and are tight and secure. Contactum would recommend that the manufacturer�s published tightening torques are adhered to.
3. What are the proposed changes? 
It is anticipated that when the third amendment of BS7671:2008 is published in January 2015 it is expected to state under new regulation 421.1.200: 
Within domestic (household) premises, consumer units and similar switchgear assemblies shall comply with BS EN 61439 3 and shall: (i). Have their enclosures manufactured from non-combustible material, or (ii). Be enclosed in a cabinet or enclosure constructed of non-combustible material and complying with Regulation 132.12. 
NOTE 1: Ferrous metal e.g. steel is deemed to be an example of a non-combustible material. 
NOTE 2:* the implementation date for this regulation is the 1st January 2016. This does not preclude compliance with this regulation prior to this date.
4. What is the intent of the new regulation?
The intent of regulation 421.1.200 is considered to be, as far as is reasonably practicable, to contain any fire within the enclosure and to minimise flames from escaping; caused mainly as a result of poorly installed connections. 
5. What is meant by ��non-combustible�? 
There is no published definition for �non-combustible� that aligns with the intent of regulation 421.1.200. Ferrous metal, e.g. steel is deemed to be one example of a non-combustible material that meets the intent of the regulation. 
6. What is meant by �within domestic (household) premises�? 
It is understood that Regulation 421.1.200 applies to consumer units and similar switchgear assemblies to BS EN 61439-3 inside all domestic (household) premises including their integral/attached garages and outbuildings or those in close proximity.
7. What impact will this regulation have? 
This would mean that eventually all new consumer units installed in UK homes, i.e. within domestic (household) premises, as defined in point 6 above; must have their enclosures manufactured from a non-combustible material, or be enclosed in a cabinet or enclosure constructed from a non-combustible material. Metal (Steel) enclosures are deemed to offer the best non-combustible characteristics.
8. Has Contactum been involved with these proposed changes?
Contactum have been closely involved in the development of these changes by providing expert industry liaison with interested bodies which including BEAMA (British Electrotechnical and Allied Manufacturers Association). Contactum are committed to delivering the highest quality products which afford maximum consumer safety.
9. When will Amendment 3 come into effect?
The third amendment to BS 7671:2008 will be issued in January 2015 and is intended to come into effect on 1st July 2015. Installations designed after 30th June 2015 are to comply with BS 7671:2008 incorporating Amendment 3, 2015. 
However, Regulation 421.1.200 does not come into effect until the 1st January 2016. This does not preclude compliance with this regulation prior to this date.
10. Does this mean all installed consumer units with plastic enclosures are a fire risk?
No, provided the consumer unit and its incorporated components conform to the relevant product standard(s), do not have latent defects, and have been installed correctly to the manufacturer�s instructions.